Installation (for qualified installers only) 55
© Travis Industries 3/13/18 - 1474 42 & 54PB GSB2 Aust.
8. Install the LP pilot orifice following the instructions below.
(a) Use a 7/16” open-end wrench to remove the pilot hood.
(b) Remove and discard the Natural Gas (NG) orifice. Place the LP orifice in the pilot assembly then replace the pilot
hood, tightening the pilot hood until it is snug (do not over-tighten).