99
Model Three - Operation Manual
Trunk Voltage Measurement:
Input range: 10 to 100 VAC or VDC
Accuracy: ±2.0 V
Resolution: 0.1 V
Power:
11.1 V / 1.4 AH Li-Ion battery
Provides 5 hours of continuous operation
Charger: 100 to 240 VAC, 50/60 Hz, 15 VDC , 2 A (max)
Charge time: Less than three hours
Display: 128 x 128 backlit LCD
Communication Port: RS-232C (Converts to USB with data cable)
Storage: 32 Kb of memory
Up to 30 complete scan files (170 channels, max)
or 22 complete limit test files (170 channels,
max); less if other files (level, tilt, QAM, Hum,
spectrum) are saved
Weight: 1.76 lbs (800 g)
Dimensions: 8.52” x 3.74” x 1.93”
(H x W x D) (218mm x 95mm x 49mm)
(dimensions do not include belt clip)