EasyManua.ls Logo

Tritech MicronNav - Enabling the USBL Transducer Transponder Transmitter; Configure Seanet Pro for Transponder Mode

Tritech MicronNav
144 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Conversion Between MicronNav Responder and Transponder MicronNav System
0656-SOM-00001-07 134 © Tritech International Ltd.
confirm the settings and close the AM100 ModemCfgSetup page. After a few seconds the
reprogramming of the unit will be complete and "Node 85, Prog Cfg Done" will be displayed
in the status bar.
The magnet can now be removed from the body of the Responder unit and power switched off
and re-applied to activate the change. This now completes the conversion from Responder
to Transponder mode.
Close the Seanet Setup program and delete the Seanet Pro Supervisor shortcut.
11.2.1. Enabling the USBL Transducer Transponder Transmitter
Run the Seanet Setup program by clicking on the Seanet Setup icon from the desktop
or navigating to Setup from the Applications menu of an already running instance of
Seanet Pro.
Click the Action arrow button in the SEAHUBNAV100 row followed by Setup from the drop-
down menu. A warning will be displayed, read this and select OK to continue to open the
SeaHub Setup page. Click on SeaNav100 tab and activate the Transponder transmitter by
enabling the Has Transmit check box.
Confirm the settings and close the SeaHub Setup page. After a few seconds the
reprogramming of the unit will be complete and "Node 90, Prog Cfg Done" will be displayed
in the status box. The SEAHUBNAV100 entry will temporarily disappear from the list while the
unit resets to activate the change.
11.2.2. Configure Seanet Pro for Transponder Mode
To configure the Seanet Pro software to operate in Transponder mode first run the program
by selecting the Seanet Pro icon from the desktop. If the screen differs from the screen

Table of Contents