Installing the System MicronNav System
0656-SOM-00001-07 20 © Tritech International Ltd.
Now add a port for the Micron or SeaSprite Sonar connection for use when Responder mode
operation is required. This is done by selecting New from the menu bar followed by Aif from
the sub-menu. The new Aif device must now be configured to Port B by adjusting the COM
Port number with the spin edit button until the Type=”SeaHubB” as shown below, click the
check box to enable and close the ‘Channel Setup’ page by clicking the ‘X’ at the top right
of the window.