Reinstall the indicator.
✓
Press 〈ENTER〉. The compactor lowers the loading head. When
prompted, re-zero the indicator by pressing the button at the end
of the remote control cable. From the control panel display,
press 〈ENTER〉.
✓
After gyrating several times, the screen is:
✓
Read the value displayed on the digital indicator and input the
number in millimeters into the control unit.
✓
Press 〈ENTER〉. The compactor removes the angle and slightly
raises the loading head. The display is:
✓
Repeat the angle readjustment until the desired angle is
obtained. When the angle is correct, accept it by pressing 〈2〉.
To print the calibration results, press 〈YES〉 at the print
calibration prompt. The control unit returns to the Calibration
menu. To return to the Machine Idle screen press 〈ESC〉.
✓
Turn the indicator magnet off by pushing the button so it is
flush with the label.
✓
Remove and unplug the indicator. Handle the indicator with
care. DO NOT DROP OR BANG the indicator. Return the
indicator to the Performance Verification Kit.
From Indicator
And Press ENTER
1-Readjust Angle
2-Accept Angle
Select (1-2)