64
Full system teaching
In case of full system teaching, all previously recorded control
panel codes will be deleted, and new codes will be recorded in
their place. Full teaching is performed when one of the control
panels is lost and it is necessary to delete it from the system. To
log on the teaching mode, any RCP that was taught in the system
and the synchronization counter which is synchronized with the
control unit are needed. The RCP with which teaching has been
initiated becomes educative in this teaching session. When the
teaching procedure is violated, the system logs out of the teaching
mode without any results saved and the system status indication
in the cluster goes out.
Full teaching is performed in the following order:
1. Deactivate system security system;
2. Leave one of the doors open;
3. Start up the ignition;
4. Max. 1.5 s after starting ignition, press button 4 on the control
panel to be taught and hold it pressed;
5. Wait until the system status signal device in the cluster starts
blinking fast, indicating the teaching process has started (about
3 s after pressing button 4);
6. Max. 3 s after the indicator starts blinking, holding button
4 pressed, press button 2 one time. The system status signal device
stops blinking and is continuously lit. Release button 4;
7. In max. 3 s cycle the ignition;
8. Max. 3 s after starting up the ignition press button 4 on the
control panel to be taught and hold it pressed;
9. Wait until the system status signal device in the cluster starts
blinking fast (about 3 s after pressing button 4);
10. Max. in 3 s after the indicator starts blinking, holding button
4 pressed, press button 2 one time. The system status signal device
stops blinking and is continuously lit (without blinking). Release
button 4;
11. In max. 3 s cycle the ignition;