6.WEIGHING MODE SETTING AND OPERATION
84
< Example > Judging times is set to “02”
AZ times
This two-digit (00-99) number enable/disable zero-clearance of Weight value
when the metering process starts. Weight is zero-cleared using Digital Zero (if
weight is set to Gross) or Tare Subtraction (if weight is set to Net).
Complete
Judge
FF CPS.
Judging times 2 times
Average count of FF CPS. 2 times
FF CPS. reads in and stores samples for compensation synchronized with
Over/Under comparison signal.
Selecting “00” for Judging times inhibits F159 to collect these sample data,
thus disabling Free fall compensation.
Select a non-zero value for Judging times to enable Free fall
compensation.
Request
00 : Auto zeroing is disabled
01 : every time
02 : once in every two weighing processes
03 : once in every three weighing processes
99 : once in every 99 weighing processes