EasyManua.ls Logo

Unipulse F159 - Page 95

Unipulse F159
126 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6.WEIGHING MODE SETTING AND OPERATION
86
Auto jog
This parameter enable/disable (ON/OFF) the Auto jog function.
Auto jog timer 
This parameter specifies the Auto jog timer (allowable range: 0.00-9.99)
Auto Jogging is allowed only in the Sequence mode.
If Over/Under check decides that the weight is stll short of the desired value
(Under), SP3 will turns ON again until Auto jog timer expires.
10
1
10
0
10
1
10
0
Judging times 00 - 99
m+24
AZ times   00 - 99
10
0
10
0
10
0
10
0
At start WV confirmation
m+32
At start NZ confirmation
Auto jog
Mode selection
1ON
0OFF
1ON
0OFF
1Enabled
0Disabled
10
0
10
-1
10
-2
Auto jog timer 0.00 - 9.99
m+23

Table of Contents