6.WEIGHING MODE SETTING AND OPERATION
86
Auto jog
This parameter enable/disable (ON/OFF) the Auto jog function.
Auto jog timer 
This parameter specifies the Auto jog timer (allowable range: 0.00-9.99)
Auto Jogging is allowed only in the Sequence mode.
If Over/Under check decides that the weight is stll short of the desired value
(Under), SP3 will turns ON again until Auto jog timer expires.
10
1
10
0
10
1
10
0
Judging times 00 - 99
m+24
AZ times   00 - 99
10
0
10
0
10
0
10
0
At start WV confirmation
m+32
At start NZ confirmation
Auto jog
Mode selection
1ON
0OFF
1ON
0OFF
1Enabled
0Disabled
10
0
10
-1
10
-2
Auto jog timer 0.00 - 9.99
m+23