23
6 EXTERNAL INPUT/OUTPUT SIGNALS
23
EXTERNAL INPUT/OUTPUT SIGNALS
Chapter
6
6-3. External output signals
■External output selection
Each signal of comparison outputs is selectable by setting.
OUT1: Output selection 1
OUT2: Output selection 2
Select from OK, NG, HH, HI, LO, and LL.
■OK/ NG/ HH/ HI/ LO/ LL
Each signal turns ON when the comparison condition is met.
* See "5-1.HI-LO limit comparison" on page 16 to "5-4.Comparison timing" on page 18.
External output selection
Output selection 1*
Output selection 2*
* 0: OK 1: NG 2: HH 3: HI 4: LO 5: LL