35
7 OPTION
35
OPTION
Chapter
7
- Read the not linked with indicated value (sign, 5-digit, decimal point)
- Status 1
- Status 2
- Write the setting value
* For setting value No., see "■Setting value communication formats" on page 37.
- Read the setting value
* For setting value No., see "■Setting value communication formats" on page 37.
Host
F331
N
RB
+
010 00
.
O RCRB
IDNo.
ID
IDNo.
0 fixed
Delimiter
Host
F331
N
RC 000 00
0
O RCRC
IDNo.
ID
IDNo.
0
+LOAD
-LOAD
OFL2
OFL1
HH
LL
Calibration error No.
0: OFF 1: ON
0: OFF 1: ON
0: OFF 1: ON
0: OFF 1: ON
0: OFF 1: ON
0: OFF 1: ON
F331 error No.
Delimiter
Host
F331
N
RD 000 00
0
O RCRD
IDNo.
ID
IDNo.
0
Under a hold/ Under a judgment
Undefined
NZ
HI
OK
LO
LOCK
0: OFF 1: ON
0
0: OFF 1: ON
0: OFF 1: ON
0: OFF 1: ON
0: OFF 1: ON
0: Setting value LOCK and calibration value LOCK OFF
1: Only setting value LOCK is turned ON
2: Only calibration value LOCK is turned ON
3: Setting value LOCK and calibration value LOCK ON
Delimiter
Host
F331
W CRNO
IDNo.
Setting value No.
Setting value
* No data returned
(sign, 5-digit, no decimal point)
Host
F331
W
W
CRNO
IDNo.
ID
IDNo.
Setting value No.
Delimiter
Setting value
Setting value No. (sign, 5-digit, no decimal point)