- 28 -
3.3 Packages CUP1000…CUP1400
3.3.1 Performance
Notes:
1. Nominal cooling capacity based on indoor air temp.
27ºC db/19.5ºC wb and outdoor air temp. 35ºC db/24º wb.
2. Nominal heating capacity based on indoor air temp.
21ºC db and outdoor air temp. 7.5ºC db/6.1ºC wb.
3. Operating current measured at the most loaded phase.
R22
Model CUP1000 CUP1200 CUP1400
Watt 28341 35258 42204
Cooling capacity
Btu/h 96700 120300 144000
Watt 28517 35610 42614
Heating capacity
Btu/h 97300 121500 145400
Power Consumption - cooling Watt 10600 13500 16000
Power Consumption - Heating Watt 10000 12900 15220
Operating Current (cooling/Heating) Amp 19.9/19.6 23.1/22.8 26.8/26.4
E.E.R - Energy Efficiency Ratio Cooling 9.1 8.9 9.0
C.O.P - Coefficient Of Performance Heating 2.9 2.8 2.8
Moisture Removal Lit/h 11.7 14.6 16
Power Supply V/Ph/Hz 400V, 3Ph, 50Hz
Time Delay Fuse Amp. 3xC-32 3xC-40 3xC-40
R407C
Model CUP1000 CUP1200 CUP1400
Watt 27842 34583 41324
Cooling capacity
Btu/h 95000 118000 141000
Watt 28000 34500 41500
Heating capacity
Btu/h 95540 117700 14160
Power Consumption - cooling Watt 10500 13400 15900
Power Consumption - Heating Watt 9830 12650 14950
Operating Current (cooling/Heating) Amp 19.5/19.3 22.8/22.4 26.3/26.0
E.E.R - Energy Efficiency Ratio Cooling 9.04 8.8 8.86
C.O.P - Coefficient Of Performance Heating 2.85 2.72 2.77
Moisture Removal Lit/h 11.7 14.6 16
Power Supply V/Ph/Hz 400V, 3Ph, 50Hz
Time Delay Fuse Amp. 3xC-32 3xC-40 3xC-40