Code 93 
 
< Default All Code 93 Settings > 
 
Code 93 On/Off 
 
 
 
Code 93 Message Length 
Scan the bar codes below to change the message length. Refer to Message Length 
Description (page 49) for additional information. Minimum and Maximum lengths = 0-80. 
Minimum Default = 0, Maximum Default = 80. 
 
 
 
Code 93 Append 
This function allows the scanner to append the data from several Code 93 bar codes together 
before transmitting them to the host computer. When this function is enabled, the scanner 
stores those Code 93 bar codes that start with a space (excluding the start and stop symbols), 
and does not immediately transmit the data. The scanner stores the data in the order in which 
the bar codes are read, deleting the first space from each. The scanner transmits the 
appended data when it reads a Code 93 bar code that starts with a character other than a 
space. Default = Off.