What is it doing? Possible causes Check and correct
n The camera is connected
via RS-232
n The camera does not have
IP streaming capability
n IP streaming is not enabled
on the camera
The display connected to the
camera controller's HDMI
output shows a black screen.
The display is powered off. Power on the display.
The camera controller's video
mute pattern is set to "black
screen" and no video stream is
available from the selected
camera (always true for RS-
232 connected cameras), or no
camera is selected.
This is normal.
The display connected to the
camera controller's HDMI
output shows a blue screen.
The selected IP-connected
camera's video is muted, and
the camera is streaming a blue
screen as its video mute
pattern.
Unmute the camera's video.
The display connected to the
camera controller's HDMI
output shows random colored
lines.
The color space or resolution is
set to a value that the display
does not support.
Change the resolution or color space for
the video output port (web interface,
PCC Settings page).
Operation, Storage, and Care
For smears or smudges on the product, wipe with a clean, soft cloth. Do not use any abrasive chemicals.
Keep this device away from food and liquids.
Do not operate or store the device under any of the following conditions:
n Temperatures above 40°C (104°F) or below 0°C (32°F)
n High humidity, condensing or wet environments
n Inclement weather
n Severe vibration
n Dry environments with an excess of static discharge
Do not attempt to take this product apart. There are no user-serviceable components inside.