USER'S GUIDE ____________________________________________________________________
66 __________________________________________________________________ M210543EN-F
After receiving the correct password, the system requests a new
password. Press ENTER to remove the password. Otherwise, type a new
password.
Example system response to the CONF command for PWD22:
CONF. PASSWORD (4 CHARS MAX)
UPDATE CONFIGURATION PARAMETERS
UNIT ID (2 CHAR) () 1
UPDATED
SET REFERENCE PARAMETERS
OFFSET ( 156.47) Y
OFFSET REFERENCE UPDATED
MODE UPDATED
ALARM LIMIT 1 ( 0) 1500
ALARM LIMIT 1 UPDATED
ALARM LIMIT 2 ( 0) 1000
ALARM LIMIT 2 UPDATED
ALARM LIMIT 3 ( 0) 500
ALARM LIMIT 3 UPDATED
RELAY CONTROL MODE
0 = 3*VIS, 1 = 2*VIS & HW ( 0) 1
RELAY ON DELAY ( 5)
RELAY OFF DELAY ( 5)
TRANSMITTER CONTAMINATION LIMITS
WARNING LIMIT ( 0.5)
ALARM LIMIT ( 3.0)
RECEIVER CONTAMINATION LIMITS
WARNING LIMIT ( 300)
ALARM LIMIT ( 600)
ANALOG OUTPUT MODE
0=LINEAR, 1=LN, 2=EXTI, 3=VGI, 4=VG2 ( 4)
ANALOG OUTPUT RANGE
MAX VISIBILITY ( 20000)
= mA ( 20.0)
MIN VISIBILITY ( 10)
= mA ( 4.0)
HOOD HEATERS USED 1=YES, 0=NO ( 0)
END OF CONFIGURATION
The output illustrates the response to the command when using PWD22.
With PWD52 the maximum visibility is 35000 meters. The system
responses are otherwise identical
for PWD22 and PWD52.