USER'S GUIDE ____________________________________________________________________  
66  __________________________________________________________________  M210543EN-F 
After receiving the correct password, the system requests a new 
password. Press ENTER to remove the password. Otherwise, type a new 
password. 
Example system response to the CONF command for PWD22: 
CONF. PASSWORD (4 CHARS MAX) 
 
UPDATE CONFIGURATION PARAMETERS 
UNIT ID (2 CHAR) () 1 
 UPDATED 
SET REFERENCE PARAMETERS 
OFFSET (  156.47) Y 
 OFFSET REFERENCE UPDATED 
MODE UPDATED 
ALARM LIMIT 1 (      0) 1500 
 ALARM LIMIT 1 UPDATED 
ALARM LIMIT 2 (      0) 1000 
 ALARM LIMIT 2 UPDATED 
ALARM LIMIT 3 (      0) 500 
 ALARM LIMIT 3 UPDATED 
RELAY CONTROL MODE 
 0 = 3*VIS, 1 = 2*VIS & HW ( 0) 1 
RELAY ON DELAY (   5) 
RELAY OFF DELAY (   5) 
TRANSMITTER CONTAMINATION LIMITS 
WARNING LIMIT (  0.5) 
ALARM LIMIT (  3.0) 
RECEIVER CONTAMINATION LIMITS 
WARNING LIMIT (    300) 
ALARM LIMIT (    600) 
ANALOG OUTPUT MODE 
 0=LINEAR, 1=LN, 2=EXTI, 3=VGI, 4=VG2 ( 4) 
ANALOG OUTPUT RANGE 
 MAX VISIBILITY ( 20000) 
 = mA ( 20.0) 
 MIN VISIBILITY (   10) 
 = mA (   4.0) 
HOOD HEATERS USED 1=YES, 0=NO (     0) 
 
END OF CONFIGURATION  
 
   
The output illustrates the response to the command when using PWD22. 
With PWD52 the maximum visibility is 35000 meters. The system 
responses are otherwise identical 
for PWD22 and PWD52.