EasyManua.ls Logo

Valtra T144 - Periodical Maintenance; Running the Tractor in after a Storing Period Longer than Two Months

Valtra T144
414 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Test-run the tractor.
4.6.2 Running the tractor in after a storing period longer than two
months
You must run the tractor in after a storing period longer than two months.
Check the tyre pressures.
Remove the protective covers from the exhaust pipe and air induction pipe.
Turn the radiator fan carefully forwards and backwards, so that the shaft
works loosely (it may be stuck to the sealing ring of the coolant pump).
Check that the engine air filters are undamaged.
Wash off any anti-corrosion oil applied to the exterior of the tractor.
Check the belts' tightness.
Check the oil level in the engine and transmission.
Check the coolant level in the radiator.
Refill the AdBlue/DEF tank with new AdBlue/DEF.
Change the selective catalytic reduction (SCR) system supply module main
filter.
Bleed the fuel system of air.
Refit the battery (fully charged).
IMPORTANT: Make sure that the main power is turned off before
disconnecting or reconnecting the battery.
Start the engine without racing it.
Test-run the tractor.
4.7 Periodical maintenance
5
20
30
40
50
0
5
0
20
25
30
1
GUID-56496CFD-9F29-4A47-9BBC-E980432028AF
1. Periodical maintenance view