EasyManua.ls Logo

VAT 642 Series - Technical Data; Control and Actuating Unit

Default Icon
107 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Series 642 DESCRIPTION OF PRODUCT
813316EB Edition 2017-11-24 7/
107
1.6 Technical data
1.6.1 Control and actuating unit
Description
Input voltage
1)
+24 VDC (±10%) @ 0.5 V pk-pk max. [connector: POWER]
Power consumption 55 W (standard)
with optional SPS + 36 W
with optional PFO + 10 W
[connector: POWER]
Interface
remote
[connector: CC-Link]
local (RS232)
[connector: SERVICE]
LOGIC I/O
2)
(configurable)
1 digital input
[connector: Logic I/O]
1 digital output
Sensor power supply output
3)
+24 VDC / 1500 mA max. [connector: SENSOR]
Sensor input
Signal input voltage / Input resistance
ADC resolution
Sampling time
0-10 VDC / Ri>100 k (linear to pressure)
0.23 mV
10 ms
[connector: SENSOR]
PFO
4)
battery pack
Charging time
Durability
2 minutes max.
up to 10 years @ 25°C ambient
refer to «Durability of power fail battery» for details
Ambient temperature 0 °C to +50 °C max. (<35 °C recommended)
Ambient humidity 0 to 95% RH, non-condensing
Pressure control accuracy 5 mV or 0.1% of setpoint, whichever is greater
1)
Internal overcurrent protection by a PTC device.
2)
Refer to chapter: «LOGIC I/O» for details.
3)
Refer to chapter «Sensor supply concepts» for details.
4)
PFO = Power Failure Option. Refer to «Behavior in case of power failure» for details.