ВШПА.421412.304 И1 SCIENTIFIC-PRODUCTION ENTERPRISE VIBROBIT LLC
Module cold start
Cold start is meant for writing default operating parameters to volatile memory. This function is beneficial during
initial Module powering on or in the case, when module recalibration is to be carried out or known operating
parameters are to be set.
Switching to “Cold start” mode is implemented by pressing and holding down Reset” key during entire cycle of
identification information displaying and module initialization after resetting.
If module transfers to Cold start mode, then:
MK40-DC option – “Ok” LED starts glowing yellow simultaneously with “War” LED.
MK40-DC-11, MK40-DC-001 and MK40-AC-11-S options – “Cold” message starts flashing on 7-
segment display.
After switching to cold start mode, the module “Cold start” mode must be confirmed. Confirmation of “Cold start”
mode is “Reset” key pressing sequence, which is similar to Module resetting sequence in normal operating conditions
(short-term pressing, pressing and holding down of “Reset” key).
At confirmation of the module “Cold start” mode, module settings are initialized by default setup and written to
volatile memory, after which the module is reset. If “Cold start” mode is not confirmed, module does over to normal
operation.
MK40-DC option
During settings writing to volatile memory, War” LED flashes. Writing results can be determined by “Ok LED
glowing color:
Green – writing is successful and error free.
Yellow – one or several data sections has been written to volatile memory at the second attempt.
Red – one or several data sections has been written to volatile memory with error.
MK40-DC-11, MK40-DC-001 and MK40 -AC-11-S options
During writing “Load” message is displayed. Writing results can be determined by “Ok” LED glowing color (in the
same manner as for “Slim” option) and displayed message:
“Good” - writing is successful and error free.
“Bad” – one or several data sections has been written to volatile memory at the second attempt.
“Err” – one or several data sections has been written to volatile memory with error.
Results of operating parameters writing to volatile memory are displayed for 2 seconds, after which the module
is reset automatically.