936.7 Room temperature influence, heating/cooling circuit 4
With room temperature influence, the set flow temper-
ature determined from the heating curve is adjusted
according to the room temperature.
The higher the room temperature influence is set, the
greater the adjustment of the set flow temperature will
be.
Necessary conditions for room temperature influence:
Room temperature sensor is connected.
Weather-compensated mode is set.
Parameter 936.6 set to 7.
1100 Speed settings for secondary pump in heating mode
Note
See also chapter "Flow rate control with Hydro Auto-
Control".
1100.0 Min. speed, secondary pump
Do not adjust! Minimum speed of the internal secondary pump for the
following cases:
Heating of integral buffer cylinder
Defrost
Frost protection for the heat pump
1100.1 Max. speed, secondary pump
Do not adjust! Maximum speed of the internal secondary pump for
the following cases:
Heating of integral buffer cylinder
Defrost
Frost protection for the heat pump
1100.2 Secondary pump set speed
Do not adjust! Set speed of the internal secondary pump for the fol-
lowing cases:
Heating of integral buffer cylinder
Defrost
Frost protection for the heat pump
1102 Speed settings for heating circuit pump, heating/cooling circuit 1
Note
See also chapter "Flow rate control with Hydro Auto-
Control".
1102.0 Heating circuit pump min. speed, heating/cooling circuit 1
Only change the factory setting if the minimum flow
rate in heating/cooling circuit 1 is not reached: See
chapter "Flow rate control with Hydro AutoControl".
Minimum speed of the internal heating circuit pump for
room heating/room cooling, heating/cooling circuit 1
Parameter group for heating/cooling circuit
936 Properties, heating/cooling circuit 4 (cont.)