Viessmann VITOCAL 250-A - 1396.1 Summer Saving Temperature Threshold, Heating;Cooling Cir- Cuit 2; 1397 Heating Limit: Economy Function, Outside Temperature, Heating; Cooling Circuit 3; 1397.0 Enable Summer Economy Control, Heating;Cooling Circuit 3; 1397.1 Summer Saving Temperature Threshold, Heating;Cooling Cir- Cuit 3

Viessmann VITOCAL 250-A
200 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
79
Value Meaning
0 Economy function inactive
1 Economy function active
1396.1 Summer saving temperature threshold, heating/cooling circuit 2
Heating limit for economy function, outside tempera-
ture, heating/cooling circuit 2:
The economy function can be activated so that the
rooms are not heated unnecessarily when outside tem-
peratures are mild (parameter 1396.0). The required
limit temperature (heating limit) is set for heating/cool-
ing circuit 2 in this parameter.
If the adjusted outside temperature (parame-
ter 919.0) exceeds the limit temperature by 2 K,
room heating is switched off. The heating circuit
pump is off.
If the adjusted outside temperature falls 2 K below
the limit temperature, room heating is switched on.
The heating circuit pump is running.
1397 Heating limit: Economy function, outside temperature, heating/cooling circuit 3
1397.0 Enable summer economy control, heating/cooling circuit 3
Heating limit, heating/cooling circuit 3:
The economy function can be activated so that the
rooms are not heated unnecessarily when outside tem-
peratures are mild. The required limit temperature
(heating limit) is set for heating/cooling circuit 3 with
parameter 1397.1.
If the adjusted outside temperature (parame-
ter 919.0) exceeds the limit temperature by 2 K,
room heating is switched off. The heating circuit
pump is off.
If the adjusted outside temperature falls 2 K below
the limit temperature, room heating is switched on.
The heating circuit pump is running.
Value Meaning
0 Economy function inactive
1 Economy function active
1397.1 Summer saving temperature threshold, heating/cooling circuit 3
Heating limit for economy function, outside tempera-
ture, heating/cooling circuit 3:
The economy function can be activated so that the
rooms are not heated unnecessarily when outside tem-
peratures are mild (parameter 1397.0). The required
limit temperature (heating limit) is set for heating/cool-
ing circuit 3 in this parameter.
If the adjusted outside temperature (parame-
ter 919.0) exceeds the limit temperature by 2 K,
room heating is switched off. The heating circuit
pump is off.
If the adjusted outside temperature falls 2 K below
the limit temperature, room heating is switched on.
The heating circuit pump is running.
1398 Heating limit: Economy function, outside temperature, heating/cooling circuit 4
1398.0 Enable summer economy control, heating/cooling circuit 4
Heating limit, heating/cooling circuit 4:
The economy function can be activated so that the
rooms are not heated unnecessarily when outside tem-
peratures are mild. The required limit temperature
(heating limit) is set for heating/cooling circuit 1 with
parameter 1398.1.
If the adjusted outside temperature (parame-
ter 919.0) exceeds the limit temperature by 2 K,
room heating is switched off. The heating circuit
pump is off.
If the adjusted outside temperature falls 2 K below
the limit temperature, room heating is switched on.
The heating circuit pump is running.