76
The set flow temperature for heating mode results from
the following:
■
Weather-compensated heating mode: In line with the
set heating curve and the set room temperature
■
Room temperature-dependent heating mode (room
temperature sensor required): From the differential
between the set and the actual room temperature
If the calculation results in a higher set flow tempera-
ture than the value set here, the set flow temperature
will be limited to this value.
Note
■
Since the heat pump control unit only limits the set
value with this parameter, a temperature limiter for
restricting the maximum temperature (accessories)
must be installed in the flow of an underfloor heat-
ing circuit.
■
If heating/cooling circuit 1 is a directly connected
heating/cooling circuit without mixer, the max. set
flow temperature cannot be adjusted.
In this case, the max. set flow temperature is equiva-
lent to the highest required set system flow tempera-
ture.
1193 Set flow temperature limits, heating/cooling circuit 2
1193.0 Min. flow temperature, heating, heating/cooling circuit 2
Set flow temperature limit for heating mode via heat-
ing/cooling circuit 2
The set flow temperature for heating mode results from
the following:
■
Weather-compensated heating mode: In line with the
set heating curve and the set room temperature
■
Room temperature-dependent heating mode (room
temperature sensor required): From the differential
between the set and the actual room temperature
If the calculation results in a lower set flow temperature
than the value set here, the set flow temperature will
be limited to this value.
This value cannot be set higher than max. value in
parameter 1193.1.
1193.1 Max. flow temperature, heating, heating/cooling circuit 2
Set flow temperature limit for heating mode via heat-
ing/cooling circuit 2
The set flow temperature for heating mode results from
the following:
■
Weather-compensated heating mode: In line with the
set heating curve and the set room temperature
■
Room temperature-dependent heating mode (room
temperature sensor required): From the differential
between the set and the actual room temperature
If the calculation results in a higher set flow tempera-
ture than the value set here, the set flow temperature
will be limited to this value.
Note
■
Since the heat pump control unit only limits the set
value with this parameter, a temperature limiter for
restricting the maximum temperature (accessories)
must be installed in the flow of an underfloor heat-
ing circuit.
■
For heat pump type ... 2C, heating/cooling circuit 2
can be connected directly to the heat pump.
In this case, the max. set flow temperature cannot be
higher than the max. value for heating/cooling cir-
cuit 1 in parameter 1192.1.
1194 Set flow temperature limits, heating/cooling circuit 3
1194.0 Min. flow temperature, heating, heating/cooling circuit 3
Set flow temperature limit for heating mode via heat-
ing/cooling circuit 3
The set flow temperature for heating mode results from
the following:
■
Weather-compensated heating mode: In line with the
set heating curve and the set room temperature
■
Room temperature-dependent heating mode (room
temperature sensor required): From the differential
between the set and the actual room temperature
Parameter group for heating/cooling circuit
1192 Set flow temperature limits,… (cont.)
6218234
Parameter