System Verification and Management
535-0045-00 Rev 02
Violin 6000 Series Memory Array Installation Guide
43
Verifying the Memory Gateway Power State
1. Check the power status of the Memory Gateways by running the show array modules
type mg detail command, as shown in the following example.
2. Verify that the “Power” field for both is set to “yes” and that the current draw measured is
greater than 0.
3. If one or both Memory Gateways fail to meet these criteria, power on a Memory Gateway by
running the following commands. Where <ID> is either mg-a or mg-b, depending on which
system is not powered on:
no array modules id <ID> enable
array modules id <ID> enable
4. Wait about 5 seconds after issuing the second command, and then run the show array
modules type mg detail command again. If both Memory Gateways are not reporting as
they should, see Troubleshooting on page 47.
violin-acmb [violin: master] # show array modules type mg detail
mg-a:
Present : yes
Running : yes
Mfg serial : 47201T00126
Mfg model : 410-0156-00_R02
Mfg version : 02
Mfg date : 02242012
Power : yes
Current (mA) : 5521.61
Overcurrent :
Internal switch port: 6
IP address : 169.254.1.101
HW address : 00:10:6F:16:07:31
mg-b:
Present : yes
Running : yes
Mfg serial : 47201T00135
Mfg model : 410-0156-00_R02
Mfg version : 02
Mfg date : 02242012
Power : yes
Current (mA) : 6590.08
Overcurrent :
Internal switch port: 4
IP address : 169.254.1.102
HW address : 00:10:6F:22:06:F4