EasyManua.ls Logo

Vishay 7000 - Example Responses

Vishay 7000
142 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Vishay Micro-Measurements System 7000 Programmer’s Reference Manual
Page 104 of 142
7.3.1 Example Responses
Example 1:
The following sequence commands the system to set the time-based recording mode for Groups
A and B on cards 1 and 4 to ‘Continuous’:
0x0008 0x02 0x0002 0x0009 0x00 0x03 0x01
If successful, the system will return:
0x0008 0x02 0x0002 0x0009 0x00 0x06 0x06
Note that an acknowledgement is returned for both cards.
If card 1 detects an invalid recording mode and card 4 is successful, the system will return:
0x0009 0x02 0x0002 0x0009 0x00 0x15 0x50 0x06
Note that card 1 returned a NAK followed by an error code and card 4 returned an ACK.
Example 2:
The following sequence queries the system for the channel recording group for channels 1 and 3
on cards 2 and 10.
0x0006 0x06 0x8001 0x0202 0x05
Notice the query bit is set in the command code.
If successful, the system will return:
0x0014 0x06 0x8001 0x0202 0x05 0x06 0x01 0x06 0x02 0x06 0x03 0x06 0x04
Note that an acknowledgement is returned for all channels on each card. Card 2/Channel 1 is
set to group A (0x01), Card 2/Channel 3 is set to Group B (0x02), Card 10/channel 1 is set to
group C (0x03), and Card 10/Channel 3 is set to Group D (0x04)
If card 2/channel 3 detects an error the response will change to:
0x0014 0x06 0x8001 0x0202 0x05 0x06 0x01 0x06 0x31 0x15 0x49 0x06 0x04

Table of Contents