7.4.2.3 Set Time-Based Recording Mode Command
Length
Command
Group
Command
Code
Card Mask Channel
Mask
Parameters
0x0008 0x02 0x0002 Used Ignored
0x00
Byte 8:
Group number
Multiple groups can be
specified by logically ORing
the values:
0x01
Group A
0x02 Group B
0x04 Group C
0x08 Group D
Byte 9:
Mode
0x00
Off
0x01 Continuous
0x02 Burst
Off - disables time-based recording for the selected group (default)
Continuous - records data continuously
Burst - records data continuously in bursts
7.4.2.4 Set Time-Based Recording Count Command
Length
Command
Group
Command
Code
Card Mask Channel
Mask
Parameters
0x000E 0x02 0x0003 Used Ignored
0x00
Bytes 8-15
64-bit recording
count, in scans.
The most
significant 3 bytes
will be ignored
and should be
0x000000.
Specifies the number of scans to be recorded using time based recording. If a value of 0 is specified, time
based recording will not stop based on the number of scans recorded.
Range: 0 to 1099511627775
Default: 0