7.4.4 Limits Group
Limits group commands are only valid while the system is in the idle state.
7.4.4.1 Set Limit Type Command
Length
Command
Group
Command
Code
Card Mask Channel
Mask
Parameters
0x0007 0x04 0x0001 Used Ignored
0x00
Byte 8:
Limit Type:
0x00
None, default
0x01
Incremental
0x02
Range
0x03
Normal
This command sets the limits-based recording mode for the selected card(s).
7.4.4.2 Set Number of Limit Event Conditions Command
Length
Command
Group
Command
Code
Card Mask Channel
Mask
Parameters
0x0008 0x04 0x0002 Used Used
Bytes 8-9:
The number of limit
conditions.
This command sets the number of limit event conditions for the selected channel(s).
Range: 0 to 50
Default: 0