SUPREMA - OPERATION & SERVICE MANUAL
Page 22 of 58 02-2012 Suprema - Operation & Service
Setting the Bottom Pause Delay
This feature allows a delay in the position of the bottom pause to obtain maximum vacuum and
capacity in the brewer. For example, if this setting is at 0.5 seconds, the bottom pause will
occur 0.5 seconds after the switch reads the pause position on the cam. The piston will stop
lower in the cylinder, creating more vacuum and increasing the quantity of liquid that can be
pulled into the cylinder.
1. To set the "
DELAY PAUSE", press the "UP" button on the hidden menu scroll buttons
and scroll until the following message appears,
a) Press the "START" button to enter the set mode.
b) Using the hidden setting adjustment buttons, increase or decrease the timing for the
bottom pause delay.
c) To exit the "
SET DELAY PAUSE" mode and proceed to the next setting, press the
"
UP" or "DOWN" scroll buttons.
Canceling Messages (Messages ON, OFF or "ACTIVE")
The following is a list of all the cancelable messages in this version of software. Most of these
messages can also be programmed to be "active", meaning they will disable the unit until the
message has been cleared. Use this chart as a quick reference.
1. To cancel one of the passive messages, or to make the message "active", press the
"
UP" button on the hidden menu scroll buttons until the following message appears,
a) Press the "START" button to enter the set mode.
b) Scroll through the messages by pressing the "
START" button.
c) To cancel a message or to make it "
ACTIVE", once it is displayed on the LCD press
either one of the two hidden setting adjustment buttons to switch it to "
OFF" or "
ON
-ACTIVE".
d) Press “
START” to save the settings.
e) To enable a message again, repeat the above procedure and switch the message to
"
ON" (either passive or active).
f) To exit, press one of the hidden scroll buttons.
DELAY PAUSE
PRESS <START>
MESSAGES ON/OFF
PRESS <START>
Note1:
The upper half of the
display indicates
which message is to
be canceled, and the
lower half of the
display indicates the
status of the
message (ON-
PASSIVE, ON-ACTIVE, or
OFF). All new units
are factory set with
every message set
to “ON-PASSIVE”.
Note2:
Each of the
messages in the
table can be
individually set to
“ON-ACTIVE”. Please
be aware that if a
message is set to
“ON-ACTIVE”, the
function
corresponding to
that message will be
disabled when the
message appears.
Make sure to inform
the caretaker of the
proper procedure
required to clear the
messages.