EasyManua.ls Logo

VTI Instruments EX1000A - Configure General Trigger Model Parameters

VTI Instruments EX1000A
320 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
VTI Instruments Corp.
110 EX10xxA Programming
Example #1: This code block enables trigger on the timer only.
ViUInt16 vtb_masks[4] = {0,0,0,0};
ViUInt16 dio_masks[4] = {0,0,0,0};
ViUInt16lan_masks[4] = {0,0,0,0};
vtex10xxA_set_trigger_sourceEx(vi, vtb_masks, dio_masks, lan_masks, 1, 0, 0);
Example #2: This code block enables trigger on a positive level on DIO channels 0 through 3 and a
negative edge on VTB channel 6.
ViUInt16 vtb_masks[4] = {0,64,0,0};
ViUInt16 dio_masks[4] = {0,0,0x0F,0};
ViUInt16lan_masks[4] = {0,0,0,0};
vtex10xxA_set_trigger_sourceEx(vi, vtb_masks, dio_masks, lan_masks, 0, 0, 0);
Example #3: This code block enables software trigger only.
ViUInt16 vtb_masks[4] = {0,0,0,0};
ViUInt16 dio_masks[4] = {0,0,0,0};
ViUInt16lan_masks[4] = {0,0,0,0};
vtex10xxA_set_trigger_sourceEx(vi, vtb_masks, dio_masks, lan_masks, 0, 0, 0);
The current TRIG source is queried with the vtex10xxA_get_trigger_source query.
The TRIG count is configured with the vtex10xxA_set_trigger_count function, specified with a
value from 1 to (2
31
-1). This value is reset with each ARM event.
Example: This code block sets a TRIG count of 10.
vtex10xxA_set_trigger_count(vi, 10);
The current TRIG count is queried with the vtex10xxA_get_trigger_count query.
Alternatively, the TRIG count can be set to infinity, overriding any manual setting of TRIG count,
with the vtex10xxA_set_trigger_infinite function. This function simply accepts a Boolean value
indicating the enable status of an infinite TRIG count.
The current setting of an infinite TRIG count is queried with the vtex10xxA_get_trigger_infinite
query.
The TRIG delay is configured with the vtex10xxA_set_trigger_delay function, specified with a
value in seconds from 0 to 4294 with a resolution of 0.000001 (1 µs). The TRIG delay is the time
between the recognition of the TRIG event and the execution of the scan list.
Example: This code block sets a TRIG delay of 5 ms.
vtex10xxA_set_trigger_delay(vi, 0.005);
The current TRIG delay is queried with the vtex10xxA_get_trigger_delay query.
Configure general trigger model parameters
The timer interval for Timer source events is configured with the vtex10xxA_set_trigger_timer
function, specified with a value in seconds from 0.001 (1 ms) to 4294 with a resolution of 0.000001
(1 µs). The timer interval controls the frequency of the Timer event source. The same value is used
for both arm and trigger events.