EX10xxA Function Calls 159
vtex10xxA_get_channel_type
FUNCTION PROTOTYPE
ViStatus _VI_FUNC vtex10xxA_get_channel_type(ViSession vi, ViInt32 channel, ViPInt32 type);
FUNCTION PARAMETERS
vi = contains a session handle to the instrument. This handle is obtained by the function and remains valid until the
session is closed.
channel = the channel for which the range value is desired. Valid input values: 0 through 47.
type = indicates the measurement type of the specified channel. Valid return values: 0 through 3. See Description
below for more information.
DATA ITEM RESET VALUE
Not applicable to this function.
DESCRIPTION
This function returns whether specified channel is voltage or thermocouple channel.
Valid return values for the type parameter are:
Decimal
Value
#define Symbol
type Description
0
VTEX10XXA_CHANNEL_TYPE_NONE
None
1
VTEX10XXA_CHANNEL_TYPE_TC_ONLY
Thermocouple only
2
VTEX10XXA_CHANNEL_TYPE_GP_VOLT
Voltage only
EXAMPLE