VTI Instruments Corp.
310 EX10xxA Preparation for Use
SECTION 12
QUICK REFERENCE GUIDE FOR RX1032
Mechanical Accessories
1) Power Connector: 27-0673-315, CONN, MIL-C-26482-1, CABLE PLUG, SIZE 14, 15 WAY,
SOCKET
2) Ethernet Connector: 27-0926-008I, CONN,IP67,RJ-45,PL,8POS,ST
3) Mounting Angle Bracket: 41-0604-012 (2 ea)
4) Screw, M6X10mm: 37-1901-010 (6 ea)
5) Cable Mount Bracket: 41-0604-013 (2 ea)
6) Screw, M3X6mm: 37-0223-006 (4 ea)
NOTE: Mechanical accessories need to order separately
Assembly Procedure
1) Mount option-I: 6X M6 tapped holes are provided at the bottom of the chassis as per Figure 12-1
for fixing on horizontal plate or with vibration mount.
2) Mount option-II: The System using Left and Right angle plates provided in the chassis.
3) Mount the unit to the protected area with mounting details provided as per Figure 102-1
4) Hole size in the mounting angle bracket is 6.5 mm (dia). Use 6 X M6 X 10mm LG, CAP FLANGE
HD, 10.9 STEEL SCREWS
FIGURE 12-1: RX10XX CHASSIS MOUNTING DETAILS
5) Remove the Top Cover by opening 3 Latches on right and left side of chassis.