Chapter 4: Description of functions (abbreviated)
49
P5.28
IMPULS minimum input
0.00kHz to P5.30
0.00kHz
P5.29
Corresponding
minimum input impulse
setting
-100.0% to 100.0%
0.0%
P5.30
IMPULS maximum input
P5.28 - 100.00kHz
50.00kHz
P5.31
Corresponding
maximum input impulse
setting
-100.0% - 100.0%
100.0%
P5.32
Filter time of impulse
curve
0.00S - 10.00s
0.10s
P5.33
Selection of FI curve
Units: FIV curve selection
1: Curve 1 (2-point, see P5.13 - P5.16)
2: Curve 2 (2-point, see P5.18 - P5.21)
3: Curve 3 (2-point, see P5.23 - P5.26)
4: Curve 4 (4-point, see C6.00 - C6.07)
5: Curve 5 (4-point, see C6.08 - C6.15)
Tens: Choice of FIC curves (1-5, same as FIV)
Hundreds: Choice of FIA curves (1 - 5, same as
FIV)
321
P5.34
Set the FI to less than
the minimum input up
Units: Setting the FIV to a value less than min.
entrance
0: Minimum value
1: 0.0%
Tens: Setting the FIC to a value less than min.
input (0 - 1, same as FIV)
Hundreds: Setting the FIC to a value less than
min. input (0 - 1, same as FI)
000