EasyManua.ls Logo

VYBO Electric Vector V810 - Page 67

VYBO Electric Vector V810
106 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 4: Description of functions (abbreviated)
63
P9.43
On time at the 1
st
fault
-
-
P9.44
Runtime after the 1
st
fault
-
-
P9.45
Reserved
P9.46
Reserved
P9.47
Selection of failure
protection action 1
.... X: Motor overload (OL1)
0: Deceleration to a stop
1: STOP according to stop mode
2: Continuing operation
... X.: Lost of input phase LI
..X ..: Output phase loss (LO)
.X ...: External device error (EF)
X ....: Communication error (CE)
00000
P9.48
Selection of failure
protection action 2
.... X: PG encoder error
0: Deceleration to a stop
1: Switch to V / F, STOP control according to
stop mode
2: Switch to V / F control, motor RUN
continues
... X.: EEPROM memory error (EEP)
0: Deceleration to a stop
1: STOP according to stop mode
..X ..: Reserved
.X ...: Engine overheating
X ....: Total time reached (END1)
00000

Table of Contents