Chapter 4: Description of functions (abbreviated)
64
Function
code
Parameter name
Setting range
Default
setting
Property
P9.49
Selection of failure
protection action 3
....X: User defined 1
0: Deceleration to a STOP
1: STOP according to stop mode
2: Continuing in RUN
...X.: User defined 2
0: Deceleration to a STOP
1: STOP according to stop mode
2: Continuing in RUN
..X..: Total time under voltage (END2)
reached
0: Deceleration to a STOP
1: STOP according to stop mode
2: Continuing in RUN
.X...: Zero load
0: Deceleration to a STOP
1: STOP according to stop mode
2: Continues to operate at 7% of the rated
motor frequency and restores the set
frequency when the load is restored
X....: Loss of PID feedback
0: Deceleration to a STOP
1: STOP according to stop mode
2: Continuing in RUN
00000
P9.50
Selection of failure
protection action 4
Units: Excessive Speed Deviation (ESP)
0: Deceleration to a stop
1: STOP according to stop mode
2: Continue running
Tens: Speeding (OSP)
Hundreds: Initial Position Fault (INI)
00000
P9.51
Reserved
P9.52
Reserved
P9.53
Reserved