Motor short-circuit detection at power-on, output phase loss protection, over-
current protection, over-voltage protection, under voltage protection, overheat
protection and overload protection.
IEC 61000-4-6; IEC 61000-4-4; IEC 61000-4-11; IEC 61000-4-5
EN/IEC 61800-3: 2017; C1, which is suitable for the 1st environment;
EN/IEC 61800-3: 2017; C2, which is suitable for the 1st environment;
Installation in the
environment
Inside, avoid direct sunlight, salt, dust, corrosive or flammable gas, smoke, steam.
Resistance to chemical pollution Class 3C3 EN/IEC 60721-3-3. Resistance to
pollution by dust 3S3EN/IEC 60721-3-3.
Under 1000 meters (reduce the power level when used above 1000 meters above
sea level.)
-10 °C ~ 40 °C (reduce the power level if the ambient temperature is between 40° C
and 50° C)
Less than 95% relative humidity, no condensation IEC 60068-2-3
Less than 5,9 m/s2 (0,6 g) IEC 60068-2-6