4.6. Mounting pads with PTFE clamp ring
In some types of inserts (e.g. 54-B 143), the pad is xed using
a PTFE clamp ring (e.g.
54-B 002). In these cases, the pad
mounting tool on the back of the device is used for assembly
(refer to chapter 2.4).
• Install the insert on the wand (see chapter 4.2).
• Insert the clamp ring (C) into the special oval slot of the
pad mounting tool (A). To do this, apply a light pressure
with your ngers to the two opposite sides of the ring so
that it takes on an elliptical shape, then position it in place.
• Place the
54-B 026 pad (D) in the rectangular groove of the
pad insertion tool (B).
• Take the wand and push the tip on the pad insertion tool so
that the pad and the ring both t onto the electrode.
• Adjust the insert direction as needed (see chapter 4.8).