37
SURFOX 306
USER MANUAL
ACCESSORY PART No SURFOX-T SURFOX-G
Graphite insert | 100 mm
54-B 607 MID HIGH
Graphite insert | 45 mm
54-B 009 LOW MID
DW brush for S306
54-B 604 HIGH HIGH
It is important to keep the electrodes always
well wet to prevent them from overheating.
7.7. Start of processing
Before starting to pickle / polish a piece of stainless steel, check that all the preliminary operations described in chapter 5
have been carried out correctly.
Make sure the most appropriate accessory is installed on the DW wand for the type of processing to be performed.
Choose the most appropriate liquid for the type of processing to be carried out:
SURFOX-T, an heavy-duty cleaning solution suitable for both pickling and polishing.
SURFOX-G, a pH neutral cleaning solution suitable for pickling only
Always refer to the product data sheet for detailed indications regarding its eld of use.
WALTER
Customer Service (walter.com) is available for any additional information.
Acid solutions are dangerous and can cause
damage to people and property: please read
carefully the chapter 1 on the safety regulations
and personal protective equipment that must
be used when working with these substances.
Pour the electrolyte solution into a jar or plastic container
large enough to hold the insert or brush.
Fully immerse the insert with pad or brush in the container.
Turn on the device by turning the main switch (located on the front panel of the unit) to the "I" position.
Select the desired operating mode by pressing the MODE button on the control panel (see chapter 3.3 for more information).
Press the SET button to select the desired power level (see chapter 3.4 for more information).
In order not to cause excessive wear or damage to the accessories, it is recommended that you select the power level
according to the following table, which takes into account both the power supplied by the SURFOX device model used, and
the conductivity of the electrolyte solution.
The table is to be considered valid only if the manufacturer's predened voltage values are used in the various operating
modes.