6.30 Parameters Watlow Series F4P
Note: Press the Information Key ˆ for more task-related
tips.
*The tenth digit of your model number, F4PX-XXXX-XXXX,
determines what RTD calibration resistance values the unit
uses. Refer to the Ordering Information in the Appendix.
Options 1-4, 100 RTD - 15.00 and 380.00
Options 5-8, 500 or 1000 RTD - 240.00 and 6080.00
Factory Page Parameter Table Modbus
Register
Range read/write Conditions for
Parameter Description (Modbus Value) Default (I/O, Set) Parameters to Appear
Active: Always.
Output
1605 [1A]
1610 [1B]
Rexmit
1625 [1]
1630 [2]
r/w
20.000mA0.000 to 24.000mA
(0 to 24000)
20.000mA
Store 20mA calibration
for the process output.
Active: Always.
Output
1604 [1A]
1609 [1B]
Rexmit
1624 [1]
1629 [2]
r/w
4.000mA0.000mA to 6.000mA
(0 to 6000)
4.000mA
Store 4mA calibration for
the process output.
Main > Factory > Calibration > Calibrate Output x (1A or 1B) and Retransmit x (1 and 2)
Calibrate Output x (1A or 1B) and Retransmit x (1 and 2)
Active: Always.
Inputs 3 appear only if the con-
troller is the enhanced version
(F4P _ - _ _ AB - _ _ _ _).
1603 [1]
1608 [2]
1613 [3]
r/w
Yes (13)
1000 Ohms
Store 1000.00 calibra-
tion for the slidewire
input.
Active: Always.
Inputs 3 appear only if the con-
troller is the enhanced version
(F4P _ - _ _ AB - _ _ _ _).
1603 [1]
1608 [2]
1613 [3]
r/w
Yes (12)
15.0 Ohms
Store 15.00 calibration
for the slidewire input.
Active: Always.
Inputs 2 and 3 appear only if the
controller is the enhanced ver-
sion (F4P _ - _ _ AB - _ _ _ _).
1603 [1]
1608 [2]
1613 [3]
r/w
Yes (11)
20.000mA
Store 20mA calibration
for the process input.
Active: Always.
Inputs 2 and 3 appear only if the
controller is the enhanced ver-
sion (F4P _ - _ _ AB - _ _ _ _).
1603 [1]
1608 [2]
1613 [3]
r/w
Yes (10)
4.000mA
Store 4mA calibration for
the process input.
Active: Always.
Inputs 2 and 3 appear only if the
controller is the enhanced ver-
sion (F4P _ - _ _ AB - _ _ _ _).
1603 [1]
1608 [2]
1613 [3]
r/w
Yes (9)
10.000V
Store 10.000V calibration
for the process input.
Active: Always.
Inputs 2 and 3 appear only if the
controller is the enhanced ver-
sion (F4P _ - _ _ AB - _ _ _ _).
1603 [1]
1608 [2]
1613 [3]
r/w
Yes (8)
0.000V
Store 0.000V calibration
for the process input.
Active: Always.
Input
1603 [1]
1608 [2]
1613 [3]
w
Yes (7)
6080.0 Ohms*
Store 6080.00 calibra-
tion for the 500 or 1k
RTD input.