EasyManua.ls Logo

Watlow PM LEGACY PM3 - Page 57

Watlow PM LEGACY PM3
122 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Watlow PM LEGACY™ Limit Controller 57 Chapter 6 Setup Page
Setup Page
Display
Parameter Name
Description
Range Default
Modbus
Relative
Address
CIP -
Class
In-
stance
Attri-
bute
hex
(dec)
Pro-
fibus
Index
Pa-
rame-
ter
ID
Data
Type
and
Ac-
cess
**
LL.s
LL.S
Limit
Low Limit Set Point
Set the low process
value that will trigger
the limit.
-1,999.000 to
9,999.000°F or
units
-1,128.000 to
5,537.000°C
0.0°F or
units
-18.0°C
Instance 1
Map 1 Map 2
684 724
0x70
(112)
1
3
38 12003 float
RWES
sfn.a
SFn.A
Limit
Source Function A
Set the source for the
limit reset function.
nonE None (61)
dio Digital I/O
(1142)
fUn Function Key
(1001)
None Instance 1
Map 1 Map 2
- - - - 748
0x70
(112)
1
0x0F
(15)
- - - - 12015 uint
RWES
si.a
Si.A
Limit
Source Instance A
Set the instance of
the function selected
above.
1 to 12 1 - - - - 0x70
(112)
1
0x10
(16)
- - - - 12016 uint
RWES
L.Cr
LCr
Limit
Clear Limit
Clear limit once limit
condition is safe.
CLr Clear (129)
ignr Ignore (204)
- - - -
Instance 1
Map 1 Map 2
680 720
0x70
(112)
1
1
- - - - 12014 uint
W
L.st
L.St
Limit
Limit Status
Reflects whether or
not the limit is in a
safe or failed mode.
faiL Fail (32)
safE Safe (1667)
- - - -
Instance 1
Map 1 Map 2
- - - - 744
0x70
(112)
1
0x0D
(13)
- - - - 12013 uint
R
No Dis-
play
Limit
Limit State
Clear limit once limit
condition is cleared.
Off (62)
None (61)
Limit High (51)
Limit Low (52)
Error (28)
- - - -
Instance 1
Map 1 Map 2
690 730
0x70
(112)
1
6
- - - - 12006 uint
R
** R: Read, W: Write, E: EEPROM, S: User Set

Table of Contents