page 10 – 4
D-5000 / May 2000
SUPERPHONE INPUT
Internal Programming Options
Main Printed Circuit Board
Main card internal programming is accomplished via three 4-position
printed circuit board (PCB) mounted dipswitches mounted just to the left of
the module’s faders.
For main PCB programming, we will assume you are holding the removed
module upright, component side towards you, with gold-plated card fingers to the
left and the module faceplate to the right. This will enable you to read the control
legends silkscreened next to each dipswitch. Note when a dipswitch position is
thrown to the right (towards the module’s faceplate) it is ON.
Output Assign Switch Enable
As alluded to in the “VDT Programming Options” sections of the MMD
chapter (page 2-3) and the SLD chapter (page 3-4), and as indicated in Figures
4 and 5 of the “Virtual Dip Switch” chapter (page 9-6), microphone (MMD)
and stereo line (SLD) input modules can have their output assign switches
slave off of the SPD-600 phone module output assign switches. Four-position
dipswitch SW1 (top dipswitch just to the left of the module faders) enables this
feature at the phone module end:
Dipswitch position 1 activates PGM switch control
Dipswitch position 2 activates AUD switch control
Dipswitch position 3 activates AUX switch control
Dipswitch position 4 activates UTL switch control
Mutes
When the SPD-600 phone channel ON/START switch is pressed, it can
activate console mute functions. The first three positions of dipswitch SW2
(just below dipswitch SW1) determines which of the console’s three mute
lines will be activated:
SW2 position 1 mutes the control room when the phone module is ON*
SW2 position 2 mutes studio one when the phone module is ON
SW2 position 3 mutes studio two when the phone module is ON
Timer Restart
When the module is turned ON, the console’s digital timer can be
programmed to automatically reset to zero and begin counting up.
SW2 position 4 activates timer restart when the phone module’s ON/
START switch is pressed*
Tallies
Turning the module ON can activate a remote tally indicator. There are
three tally control lines: on-air, tally 2 and tally 3. The first three positions of
dipswitch SW3 (to the left of the fader) program these functions:
SW3 position 1 activates the on-air tally control line
SW3 position 2 activates tally 2
SW3 position 3 activates tally 3
Remote tallies are
hooked-up to the console
at the Control Room mod-
ule (CRD-600)
Note this feature only
works for turning slaved
assign switches ON; they
will not turn OFF from the
superphone module—this
must be done manually.
*factory default setting