34
User Manual WMF 1400
Software
Water hardness/capacity
For plumbed coffee machines with a constant water supply
(without anti-scale filter, optional), for the Aquaflex option
and for coffee machines with a water tank, the water
hardness (carbonate hardness) is set here.
With fitted filter and constant water supply or with
Aquaflex option:
Filter capacity is set here.
(The water filter capacity can be found in the water filter
documentation.)
Warm-up rinsing
Select whether the coffee machine should rinse out the
brewing unit with hot water after heating up.
Recommended setting: active.
Foamer rinsing (optional)
Automatic foamer rinsing after the last beverage dispensed
with milk components.
Yes/No
Rinsing interval
The time elapsed between the last removal of a beverage
with milk in it and a foamer rinse. Recommended setting:
2 minutes.
Operating options
The following operating options are available:
Warm rinse pad (active/inactive)•
Barista pad (active/inactive)•
• 2. Level (active/inactive)
ON/OFF button (direct/via PIN)•
Menu pad (immediately/delayed)•
If customers serve themselves then
some functions can be switched
to inactive.
The pads will not be shown on the
ready to operate display