User Manual WMF 1400
Appendix: Technical data
Mains voltage tolerance
range
120 V + 6 % - 10 %,
mains voltage interruption < 50 ms, no interruption of function
Power plug
NEMA 5-20
Mains water supply
(constant water supply
optional)
3/8 inch flexihose connector with mains tap and filter on
customer supply side, water temperature max. 95°F (35°C).
Min. 29 psi (0.2 MPa) flow pressure at 1.1 US fl. oz /h (2 l/min.),
87 psi (0.6 MPa).
Water quality
For drinking water with a carbonate hardness above 5° dkH,
a WMF water filter should be installed upstream.
Water drain pipe
(optional)
Hose min. DN 19, minimum downward slope of 0,02 inch/inch
( 2 c m / m )
Ambient temperature
+ 41°F (+ 5°C) to max. of + 95°F (+ 35°C)
(empty the water line in case of frost)
Maximum humidity
80 % relative humidity without condensation, no water spray.
Do not use unit outdoors.
Protection
IP X0
Installation clearances
For operating, service, and safety reasons the machine should
be installed with a clearance of not less than 2 inch (50 mm) at
the back and sides from the building or non-WMF components.
A clear height of 44 inch (1,100 mm) from the top of the
supporting surface should be ensured. The height of the
installation surface above the floor is at least 34 inch (850 mm).
If the machine connections are to be run downwards through
the counter, please make space for the lines, which can reduce
the usable space below the machine.
Installation dimensions of
the water filter:
(03.9314.0001)
19 inch (490 mm) (height)
4.7 inch (119 mm) (diameter)
additional space needed for connecting hoses