Maintenance
Up/Down System
3
3-18 HDSdoc091108 Maintenance
3.16 Up/Down System
1. Grease the up/down gear reducer shaft bearing with a NLGI No. 2 grade lithium grease every
1000 hours of operation.
See Figure 3-14.
2. Super model up/down systems feature a spring loaded belt design. Belt tension is automatically
maintained and requires no adjustment. Replace the belt when adequate belt tension can no
longer be obtained.
WARNING! Always secure the cutting head with a chain or a
brace before removing the up/down motor belt. The cutting head
may fall, causing severe injury or death.
FIG. 3-14