Setup & Operation
Sawmills with cable guide
2
2-2 15doc041620 Setup & Operation
See Table 2-1.
IMPORTANT! When starting the machine for the first time, check
that the main motor rotation direction is as indicated by the arrow
located on the motor body. If the rotation direction is incorrect, invert
the phases in the phase inverter in the power socket (electric box).
Setting the phases in the phase inverter correctly will ensure correct
rotation directions of all sawmill motors.
WARNING! If the blade or drive belt breaks, wait until all moving
sawmill components stop completely. Failure to do so may result in
serious injury or death.
2.2 Sawmills with cable guide
See Figure 2-1. The figure below shows setup of the sawmill and the guiding rail columns.
3 Phases
V
Fused
Disconnect
Switch
Recommended Wire
Size
400 VAC 63 A
16 mm
2
maximum length: 15 m
TABLE 2-1