Maintenance
Safety Devices Inspection (CE Version Only)
3
3-6 doc041620 Maintenance
3.10 Safety Devices Inspection (CE Version Only)
LX450 – Safety Devices Inspection
The following safety devices on the LX450 sawmill must be inspected before usage of the machine:
E-STOP button and its circuit,
Circuits with the E-STOP button pressed,
Blade cover safety switches and their circuit,
Up/down limit switches.
1. Inspection of the E-STOP Button and its Circuit (A)
Start the main motor;
Press the E-STOP button located on the left side of the control box. The main motor should be
stopped. Pressing the START button should not start the motor until the E-STOP button is
released.
See Figure 3-3.