Installation
43
Greenstar 2000 – 6 721 820 552 (2021/02)
5.5.2 Cable preparations
The appliance is factory-fitted with a 230V mains cable. It can be
replaced if a longer cable is needed or, if 230V external controls are
fitted, a multi-core cable.
NOTICE
Damage to control unit!
Small pieces of wire can cause shorts and damage to electronics.
When stripping wires always ensure copper strands do not fall into
the control box.
230V mains cable (power cables), example figure 56
Ensure the conductors (C) can reach the appropriate terminal
connection and that the protective (earth) conductor is longer than
the other wires.
Power cables connected to the appliance my have different
conductor lengths depending on the termination point.
Fig. 56 Mains voltage (power cables) preparation
Low voltage (signal cables), example figure 57
Fig. 57 Low voltage (signal cables) preparation
5.5.3 External controls - Domestic installations
Applianace external control connections example
External frost protection:
Proprietary external frost protection will only be able to be used if
external 230V controls are fitted (wired in parallel to the external
230V controls).
Worcester weather-compensating controls have built-in external
frost protection functionality ( Worcester controller Instructions
manual).
The electrical power supply to the external equipment [2] is supplied
from LS (Live), NS (Neutral) terminals and PE - \ (earth) from the
earth bar.
The Switch Live from the external equipment [3]:
–Heating (()/ zone controls connects to LR (Live Return)
terminal, remove the pre-wired link.
External frost thermostat connections [4]:
The Live supply is terminal LS.
The Switch Live is terminal LR.
Fig. 58 External controls connections example
[1] 230V mains supply to the appliance.
[2] 230V supply from the appliance to the external controls.
[3] Heating (()/ zone Switch Live (Demand) from the external
controls.
[4] External frost protection Live supply and Switch Live (Demand).
0010023711-001
> C
C
6-8mm
6-8mm
N
L
230V
0010012956-001
26-30mm
6-8mm
0-30V
L
N
L
N
N
S
L
S
L
R
5AF
L
N
1
230V AC
0010033034-001
OUT
IN
L
N
2
4
230V OUT
LR
3
L
S
- L
R

Table of Contents

Other manuals for Worcester GR2300iW C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Worcester GR2300iW C and is the answer not in the manual?

Worcester GR2300iW C Specifications

General IconGeneral
BrandWorcester
ModelGR2300iW C
CategoryBoiler
LanguageEnglish

Related product manuals