Settings in the service menu
57
Greenstar 2000 – 6 721 820 552 (2021/02)
Table 28 Menu 4: settings
8.2.5 Menu 5
Press the ( key and * key at the same time, until L.A is displayed.
Keep pressing the arrow key , until L.5 is displayed.
To confirm the selection: Press the OK key.
Select and set the service function.
The basic settings are depicted as highlighted in the following table.
These settings will not be reset during a factory reset.
Table 29 Menu 5: Limit values
4-b5 Device frost protection OFF: switched off
ON: switched on
This service function is only available if service
function 4-b1 is activated.
The device frost protection function switches the
burner and heating pump on when the outside
temperature falls below 5 °C. This prevents the
wall mounted boiler freezing.
4-b6 Temperature value for the system frost
protection
0 ... 5 ... 10 °C This service function is only available if the frost
protection function (service function 4-b1) was
activated.
If the outside temperature does not exceed the
frost threshold temperature, then the heating
pump in the heating circuit switches on (system
frost protection).
4-E2 Unit of temperature °C
•°F
4-F1 Reset device to basic setting YES: device is reset to factory settings
4-F2 Reset the fault display NO: fault is retained
YES: fault is reset
Service function Settings/adjustment range Remark/restriction
Service function L.5 Settings/adjustment range Remark/restriction
5-A1 Maximum flow temperature 30 … 82 °C Limits the adjustment range for the flow
temperature.
5-A2 Maximum DHW temperature 35...60 ... 80 °C Limits the adjustment range for the hot water (not
applicable on combination appliances.).
5-A3 Minimum boiler output (heating and
DHW)
GR2300iW 25 C : 19 ... 49%
GR2300iW 30 C : 16 ... 49%
Minimum heat output.

Table of Contents

Other manuals for Worcester GR2300iW C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Worcester GR2300iW C and is the answer not in the manual?

Worcester GR2300iW C Specifications

General IconGeneral
BrandWorcester
ModelGR2300iW C
CategoryBoiler
LanguageEnglish

Related product manuals