Settings in the service menu
Greenstar 2000 – 6 721 820 552 (2021/02)
58
8.2.6 Menu 6
Press the ( key and * key at the same time until L.1 appears.
Press arrow key until L.6 is displayed.
To confirm the selection: press OK key.
Selecting and setting the service function.
The basic settings are depicted as highlighted in the following table.
Table 30 Menu 6: function checks
8.2.7 Menu 0
Press the ( key and * key at the same time until L.1 appears.
Press arrow key until L.0 is displayed.
To confirm the selection: press OK key.
Selecting and setting the service function.
The basic settings are depicted as highlighted in the following table.
Table 31 Menu 0
Service function Settings/adjustment range Remark/restriction
6-t1 Permanent ignition OFF: switched off
•ON: switched on
Testing the ignition by means of permanent
ignition without gas supply.
To prevent damage to the ignition
transformer: Leave the function switched on
for a maximum of 2 minutes.
6-t2 Permanent fan operation 0 … 100 % Fan running without gas supply or ignition.
6-t3 Permanent pump operation (heating
pump)
0 … 100 % If a value >0 is set, the pump runs with 100 %.
6-t5 3-way valve permanently in the DHW
heating position
•0: heating
1: DHW
2: (not available)
6-tA Ionisation oscillator OFF: switched off
•ON: switched on
6-tb Burner test 0 … 100 % The burner test is ended by resetting the setting
value to 0, or by exiting L.5.
Service function Settings/adjustment range Remark/restriction
0-A1 Manual operation OFF: switched off
•ON: switched on
0-A2 Set temperature in manual operation 30 … 60 ... 82 °C