EasyManua.ls Logo

Worcester GR2300iW C - Setting Values for Output; Gas Setting Values (Natural Gas)

Worcester GR2300iW C
100 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical Specifications/Logs
Greenstar 2000 – 6 721 820 552 (2021/02)
92
13.5 Setting values for output
The maximum rated heat output can be reduced to up to 50 % of the
output range (service function 3-b1).
The minimum rated heat output can be increased to up to 50 % of the
output range (service function 5-A3).
13.5.1 Gas setting values (Natural Gas)
GR2300iW 25 C (NG)
Table 41 GR2300iW 25 C
GR2300iW 30 C (NG)
Table 42 GR2300iW 30 C
Display
percentage %
Heat Output
[kW]
Heat input
[kW]
Gas flow rate [l/min]
80 20.0 20.40 35.0
75 18.7 19.13 32.8
70 17.5 17.85 30.6
65 16.2 16.58 28.4
60 15.0 15.30 26.3
55 13.7 14.03 24.1
50 12.5 12.75 21.9
45 11.2 11.48 19.7
40 10.0 10.20 17.5
35 8.7 8.93 15.3
30 7.5 7.65 13.1
25 6.2 6.38 10.9
20 5.0 5.10 8.8
19 4.8 4.92 8.4
Display
percentage %
Heat Output
[kW]
Heat input
[kW]
Gas flow rate [l/min]
68 20.0 20.4 35.0
65 19.1 19.5 33.5
60 17.6 18.0 30.9
55 16.2 16.5 28.3
50 14.7 15.0 25.7
45 13.2 13.5 23.2
40 11.7 12.0 20.6
35 10.3 10.5 18.0
30 8.8 9.0 15.4
25 7.3 7.5 12.9
20 5.9 6.0 10.3
16 4.8 4.92 8.4