Commissioning
Greenstar 2000 – 6 721 820 552 (2021/02)
46
6.4 Starting the appliance
NOTICE
Damage to appliance or system!
Running the appliance:
Never run the appliance when the appliance/system is empty or
partially filled.
6.4.1 Control panel overview
Fig. 60
[1] Display
[2] (key: Heating mode on/off, set the maximum flow temperature
[3] * key: Hot water mode, adjusting the hot water temperature
[4] eco key: Toggle economy mode (pre-heat off)
[5] ok key: Save settings, Chimney sweeper key: press 5 seconds for
chimney sweep mode
[6] " key: Return/back
[7] key: To navigate through menus and decrease settings
[8] key: To navigate through menus and increase settings
[9] Pressure gauge
6.4.2 Screen display
Fig. 61 Screen display
Table 23
6.4.3 Switching on the device
The appliance is vented after initial power-up. This involves the heating
pump switching on and off at intervals (for approx. 4 minutes).
and the flow temperature appear alternately in the display.
Open automatic air vent valve.
Automatic siphon fill mode will begin when the appliance is first
powered-up.
When the flow temperature and the symbol appear alternately on
the display, the siphon filling program is active.
0010029487-001
1
2 3 4 5 6 7 8 9
0010016015-004
10 9
21 3 4 5 6
8 7
Key Explanation
[1] Digital display
Displays a temperature or appliance status/diagnostic code.
[2] Central heating (CH)
( Heating mode On
] Heating mode Off
[3] Fault indicator
Displays during a fault condition.
[4] Burner operation
Displays when the appliance is firing during a CH/DHW
mode.
[5] Internet connected (accessory)
Displays when compatible controller is connected to the
appliance (not used).
[6] Radio link connected (accessory)
Displays when compatible controller is connected to the
appliance.
[7] Chimney sweep mode
Displays during service when the appliance is set to
maximum or minimum output.
[8] Service mode
Displays when a qualified service engineer is in the service
menus.
[9] Eco mode active
Displays when in Economy mode (DHW Pre-heat/comfort
function is turned off)
[10] Domestic hot water (DHW)
* Hot water mode On
[ Hot water mode Off

Table of Contents

Other manuals for Worcester GR2300iW C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Worcester GR2300iW C and is the answer not in the manual?

Worcester GR2300iW C Specifications

General IconGeneral
BrandWorcester
ModelGR2300iW C
CategoryBoiler
LanguageEnglish

Related product manuals