Relio 4.2.x User Manual 07/2015
Page 8
Head Office : Parc dactivites Kennedy - 20, avenue Neil Armstrong 33700 Bordeaux-Merignac (France)
Tel +33 (0)5 57 928 928 Fax +33 (0)5 57 928 929 contact@worldcastsystems.com www.worldcastsystems.com
Power
An external power brick is supplied with each unit. No power or reset switch will be used. A connector
available on the rear panel triggers a hard reset when activated that will shut down the system then
power it back up after an appropriate delay.
I/O Subsystem
64 Digital Outputs
Rated for 30VDC @ 250mA each. Outputs are available through high-density connectors on the rear of the
enclosure.
With the external relay panel: supports up to 250 VAC with a max of 125 W (Voltage x Current)
supports up to 125 VDC with a max of 60 W
64 Optoisolated Digital Inputs
Rated for 5VDC 30VDC. Inputs are available through a high-density connector on the rear of the enclosure. Note:
Not compatible with TTL logic below 5V.
24 Analog Inputs
14-bit differential inputs. A high-density connector is used to make these inputs available on the rear of the
enclosure. Input voltage range -10 to +10 V
Voice Modem
AT Command set
RJ-11 phone standard, built-in jack
Voice playback and recording of custom voice files available
Generates and detects DTMF tones in voice mode
Line-in use, extension pick-up and remote hang-up detection
Caller ID type I and II
Digital Line Guard (DLG) Protection
Enclosure
19” rack mount compatible metal enclosure
1U (1.75”) height
16.75” W x 1.75” H x 10.5” D
Power-on LED indicator on front of enclosure
“Maintenance Mode” momentary switch
Maintenance Mode LED indicator on front of enclosure
Easily replaceable cooling fan