Recharging current:  Standard: 0.3A 
 Quick charging: 3.0A 
Recharging time:    Standard: 10-15hours 
  Quick recharging: 30minutes 
Recharging completed: open circuit voltage: over 12.8V     
1.4 Charging System 
1.4.1 Short circuit test 
Disconnect the grounding wire from the battery and use a 
voltmeter to connect battery negative lead wire with grounding 
wire. Set the switch at OFF position and check if it is shorted.     
 
* Attention 
Positive lead wire of multimeter is connected to negative lead 
wire of battery. 
 
If abnormality is found, check if there is short circuit on ignition switch and main wiring 
1.4.2 Charging state inspection 
While inspection, battery shall be fully charged and a multimeter be used for the test.   
Warm up the engine and then install fully charged battery onto the 
motorcycle. 
Connect voltmeter between terminals of the battery. 
Remove the main fuse and connect ammeter between the two terminals. 
Start engine and slowly raise RPM. Measure limited voltage and current. 
 
Limited voltage/rpm: 14-15V  (5.000rpm) 
If limited voltage is beyond the specified range, check voltage regulator.   
Inspect limited voltage in lighting system.   
 
* Attention 
Set multimeter to position of AC voltage 
 
1.5 Voltage-current Regulator 
1.5.1 Loop inspection on main wiring terminals 
 
Disconnect the 6P plug on the voltage-current regulator.