Quick Installation of Xima Inverter
o Open-loop Installation
Open Loop Installation
Set the rated current
(pb01) of the motor
Determining
the type of pc01 input
0 high speed priority
1 - binary
Defining 7 Multi-Speed according to the
table
(If I7 input is set to I3, I4, or I6, it will take
the role of these inputs and they will be
disabled.)
Determining
the stop method
0 distance mode
1 deceleration mode
Defining jerks and deceleration
pa11 = deceleration
pa12 = jerk at the beginning of the deceleration
pa13 = jerk at the end of the deceleration
Defining leveling and walking distance
pa08 = X3 = Distance from leveling sensor to the
floor level
pa09 = X0 = Distance from walking to the floor
level
Determining jerks and acceleration
pa11 = acceleration
pa12 = jerk at the beginning of the acceleration
pa13 = jerk at the end of the acceleration
0
1
1
0
Parameters of the rescue system
pd03 = rescue mode
pd04 = UPS power
pd06 = search time for the direction
PC11
PC12
PC13
PC14
PC15
PC16
PC17
0
0
0
1
1
1
1
0
1
1
0
0
1
1
1
0
1
0
1
0
1
I6 I4 I3
Do you have a rescue
system?
Yes
No
Fig. 24: Open-Loop-Installation guide of the Xima inverter